LC-MS/MS raises a handful of sensible questions. This page answers them in order, starting with the fundamentals and moving to applications.
Reviewed 2026-01-26. Anything still debated is marked as such rather than presented as settled.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ, also called NR1D1 and NR1D2. These receptors help regulate circadian rhythms and metabolic gene programs. The compound was developed for laboratory research, not as an approved therapeutic. Its identity is distinct from steroid hormones and selective androgen receptor modulators. Scientific interest centers on how REV-ERB activation changes gene expression in cells and animal models.
At the molecular level, SR9009 binds the ligand-binding domain of REV-ERB and strengthens recruitment of corepressor proteins such as NCoR and HDAC3. This increases repression of target genes, including Bmal1 and other clock-controlled and metabolic genes. In rodent studies, such changes have been linked to altered lipid handling, glucose metabolism, and energy expenditure. The precise chain of events between receptor binding and whole-body effects remains an active area of research. Findings in animals do not automatically translate to humans.
Laboratory studies often administer SR9009 by injection because oral absorption appears poor in rodents. Reported pharmacokinetic properties include rapid metabolism and low systemic exposure after oral dosing. Human pharmacokinetic data are sparse, so absorption, distribution, metabolism, and excretion in people are not well defined. Some research explores related REV-ERB compounds with improved drug-like properties. Regulatory approval for any REV-ERB agonist as a human medicine has not been granted to date.
Analytical methods for SR9009 typically rely on liquid chromatography coupled with tandem mass spectrometry. The technique can separate the parent compound from related substances and detect low concentrations in biological matrices. Urine and blood are common samples in anti-doping testing, while in vitro studies may use cell culture media. Rapid metabolism and low expected concentrations make method validation important for reliable identification. Exact metabolite patterns can vary by species and are not fully mapped.
Regulatory treatment of SR9009 reflects its investigational status. The compound has no approved human therapeutic indication, and sports authorities prohibit its use. It appears on anti-doping lists as a non-approved substance or metabolic modulator, depending on the list version. Products sold online as research chemicals are not quality-controlled medicines, so their identity and purity can differ from the label. Such products may also contain unlisted compounds, which complicates both testing and safety assessment.
| Property | Value | Notes |
|---|---|---|
| Chemical class | Synthetic small molecule | Studied as a REV-ERB agonist |
| Molecular formula | C20H24ClN3O4S | Reported for the neutral compound |
| Appearance | Off-white to pale yellow solid | Typical research-grade material |
| Solubility | Sparingly soluble in water | Soluble in solvents such as DMSO |
| Common synonyms | SR9009; Stenabolic | Stenabolic is an informal alias |
SR9009 is a synthetic small molecule developed as an agonist of the nuclear receptors REV-ERBα (NR1D1) and REV-ERBβ (NR1D2). These receptors help regulate circadian rhythms and metabolic gene expression. In cell and animal studies, SR9009 alters transcription of genes involved in lipid metabolism, inflammation, and mitochondrial function. It is not an approved medicine, and its pharmacological profile in humans remains largely uncharacterized. The compound is frequently discussed in the context of circadian biology and metabolic research rather than clinical use.
Preclinical reports have linked SR9009 to improved endurance and altered energy expenditure in rodents. Such findings have prompted interest in whether REV-ERB activation can influence skeletal muscle metabolism. However, the reported effects depend on dose, route, and experimental model, and replication across laboratories is limited. Human trials have not established comparable outcomes, so claims about exercise performance remain speculative. The absence of controlled human data is a central limitation in interpreting these observations.
Laboratory samples of SR9009 are typically handled as research chemicals rather than pharmaceuticals. Suppliers usually state that the material is for research use only and not for human or veterinary administration. Storage recommendations generally call for a freezer at approximately −20 °C, protection from light, and a desiccated environment. The solid is often described as a white to off-white powder. Solubility is commonly reported in organic solvents such as dimethyl sulfoxide and ethanol, with low solubility in water.
Analytical identification and purity assessment often use high-performance liquid chromatography with ultraviolet detection or mass spectrometry. Liquid chromatography–tandem mass spectrometry is used to detect and quantify SR9009 in biological matrices, including urine and blood, for anti-doping or pharmacokinetic studies. Nuclear magnetic resonance spectroscopy can confirm molecular structure. Stability depends on form and storage: the solid is generally more stable than solutions, and repeated freeze–thaw cycles may degrade samples. Purity is typically reported as a percentage from a certificate of analysis.
SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.
For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.
The source of ADP-ribose for most enzymes that perform this modification is the redox cofactor NAD+. In this transfer reaction, the N-glycosidic bond of NAD+ that bridges the ADP-ribose molecule and the nicotinamide group is cleaved, followed by nucleophilic attack by the target amino acid side chain. (ADP-ribosyl)transferases can perform two types of modifications: mono(ADP-ribosyl)ation and poly(ADP-ribosyl)ation.
Bacterial display (or bacteria display or bacterial surface display) is a protein engineering technique used for in vitro protein evolution. Libraries of polypeptides displayed on the surface of bacteria can be screened using flow cytometry or iterative selection procedures (biopanning). This protein engineering technique allows us to link the function of a protein with the gene that encodes it. Bacterial display can be used to find target proteins with desired properties and can be used to make affinity ligands which are cell-specific. This system can be used in many applications including the creation of novel vaccines, the identification of enzyme substrates and finding the affinity of a ligand for its target protein. Bacterial display is often coupled with magnetic-activated cell sorting (MACS) or fluorescence-activated cell sorting (FACS) techniques. Competing methods for protein evolution in vitro are phage display, ribosome display, yeast display, and mRNA display. Bacteriophage display is the most common type of display system used although bacterial display is becoming increasingly popular as technical challenges are overcome. Bacterial display combined with FACS also has the advantage that it is a real-time technique.
Blood factors (Factor VIII and Factor IX) Thrombolytic agents (tissue plasminogen activator) Hormones (insulin, glucagon, growth hormone, gonadotrophins) Haematopoietic growth factors (Erythropoietin, colony-stimulating factors) Interferons (Interferons-α, -β, -γ) Interleukin-based products (Interleukin-2) Vaccines (Hepatitis B surface antigen) Monoclonal antibodies (Various) Additional products (tumour necrosis factor, therapeutic enzymes) Research and development investment in new medicines by the biopharmaceutical industry stood at $65.2 billion in 2008. A few examples of biologics made with recombinant DNA technology include: Many vaccines are grown in tissue cultures. Viral gene therapy involves artificially manipulating a virus to include a desirable piece of genetic material. Viral gene therapies using engineered plant viruses have been proposed to enhance crop performance and promote sustainable production.
Sources: en.wikipedia.org
Some proteins that are disordered or helical as monomers, such as amyloid β (see amyloid plaque) can form β-sheet-rich oligomeric structures associated with pathological states. The amyloid β protein's oligomeric form is implicated as a cause of Alzheimer's. Its structure has yet to be determined in full, but recent data suggest that it may resemble an unusual two-strand β-helix. The side chains from the amino acid residues found in a β-sheet structure may also be arranged such that many of the adjacent sidechains on one side of the sheet are hydrophobic, while many of those adjacent to each other on the alternate side of the sheet are polar or charged (hydrophilic), which can be useful if the sheet is to form a boundary between polar/watery and nonpolar/greasy environments. Collagen helix Foldamers Folding (chemistry) Tertiary structure α-helix Structural motif Anatomy & Taxonomy of Protein Structures -survey Archived 2019-03-16 at the Wayback Machine NetSurfP - Secondary Structure and Surface Accessibility predictor
The 2014 Ebola outbreak killed more than 11,300 people. In the Democratic Republic of Congo (DRC), as of January 2020, this is the second largest outbreak with over 3,400 confirmed or probable cases, including more than 2,200 deaths. Regeneron used its VelociGene, VelocImmune, and VelociMab antibody discovery and production technologies and coordinated with the U.S. government's Biomedical Advanced Research and Development Authority (BARDA). The therapy was developed in 6 months and a Phase 1 trial in healthy humans was completed in 2015.
The predecessor to the CAD, termed an evaporative electrical detector, was first described by Kaufman in 2002 at TSI Inc in US patent 6,568,245 and was based on the coupling of liquid chromatographic approaches to TSI's electrical aerosol measurement (EAM) technology. At around the same time Dixon and Peterson at California State University were investigating the coupling of liquid chromatography to an earlier version of TSI's EAM technology, which they called an aerosol charge detector. Subsequent collaboration between TSI and ESA Biosciences Inc. (now part of Thermo Fisher Scientific), led to the first commercial instrument, the Corona CAD, which received both the Pittsburgh Conference Silver Pittcon Editor's Award (2005) and R&D 100 award (2005). Continued research and engineering improvements in product design resulted in CADs with ever increasing capabilities. The newest iterations of the CAD are the Thermo Scientific Corona Veo Charged Aerosol Detector, Corona Veo RS Charged Aerosol Detector and Thermo Scientific Vanquish Charged Aerosol Detectors.
Sources: en.wikipedia.org
SR9009 is a synthetic research compound that activates the REV-ERBα and REV-ERBβ nuclear receptors. It is not an approved drug and has no established human therapeutic use. Most published biological data come from cell and rodent studies.
No. SR9009 is frequently mislabeled as a SARM in online discussions, but it does not target androgen receptors. Its known mechanism involves REV-ERB nuclear receptors and circadian-metabolic gene regulation.
Human clinical data are very limited. There is no approved human use, and safety and efficacy in people are not established. Most evidence comes from preclinical models, so effects observed in animals may not apply to humans.
No. It is an investigational compound without approved therapeutic indications. It is sold for research purposes only in many jurisdictions.